A kind of an outer exposure factor
|
Property value
|
Saline (sea) fogofany intensity
|
any intensity
|
Dust (sand) flow density with particles circulation speed up to, m/s, not less
|
5
|
Meanwindspeedvalue, m/s, not less
|
20
|
Maximumgustspeedvalue, m/s, not less
|
30
|
Driving of wheeled and Ml4 rack vehicle satadistance to the guarded zone, not less
|
2
|
Railway transport driving at a distance to the guarded zone, m
|
10
|
Operation of industrial and construction mechanisms at adistance to the guarded zone, m, not less
|
15
|
Airplane and helicopter flight at analtitude over the guarded zone, m, not less
|
100
|

Parameter name
|
Parameter value
|
Maximum module length(for one zone)
|
250 m
|
Fence height
|
2,5 m
|
Number of spanned components
|
17 pcs
|
Between-support space
|
3 m
|
Type of the guard alarm for perimeter areas
|
|
Supply voltage
|
8 - 35 V
|
Current consumption in operating mode
|
1,5 mA
|
Operating temperature range
|
-40 - +50??
|
Detection probability at a confidence coefficient 0.9
|
0,99
|
Name of the component
|
Completeness
|
Surface piezoelectric guard alarm "GIURZA-050P" with sensors
|
1 pc
|
Central fence support as an assembly
|
3 pc
|
Last fence support as an assembly
|
2 pc
|
Carrying fence support as an assembly
|
80 pc
|
Spanned component
|
4700 m
|
Strainer
|
17 pc
|
Alarm cabinet
|
1 pc
|
able PK 50-2-16
|
300 m
|
Spiral wrap hose
|
10 m
|
Supply cable
|
the cable length on the customer demand
|
Data cable
|
the cable length on the customer demand
|
Remote monitoring cable
|
the cable length on the customer demand
|